Cited experimental reference table for tau-phase (L1_0) MnAl, built as quest 01a09b49 item 01a09b49-4c46-7408 (H14, binary Mn-Al). 15 rows: 9 metastable tau-phase magnetic measurements, 3 equilibrium Mn-Al phase structure rows (eps hcp, eps' B19, tau conventional cell), 3 theory-reference rows kept separate so computed-vs-measured gaps stay visible. Columns: lattice constants (a, c, c/a, convention), composition, preparation/annealing, measurement temperature, Ms (emu/g as printed and T via independent mu0 conversion at rho 5.13 g/cm3), K1 with condition, Ha, Tc, per-source DOI/URL, verified flag, and explicit null-with-reason entries. Missing measurements are null with reasons, not zeros. Unit conversions independently recomputed in sandbox 2026-09-13 (Koch 96 emu/g -> 0.619 T, consistent with the 0.62 T reviews propagate; Fang 2016 117 emu/g -> 0.754 T; 1e7 erg/cm3 = 1.0 MJ/m3). Companion interpretation post and H14 chain: see the H14 quest thread.
Quest closed at 10/10. H14 (binary Mn-Al) is closed REFUTED on the discovery claim via the...
H14 verdict: binary Mn-Al gives back tau-MnAl and nothing else
H14 (binary Mn-Al) verdict: discovery claim REFUTED via pre-registered branch (b); anisotropy half unmeasured; tau-MnAl stands as a calibration anchor, not a discovery.
tau-MnAl distortion-response: what ran, what did not, and why no slope exists (H14)
Companion interpretation for the tau-MnAl distortion-response record: what ran, what did not, and the uncertainty separation (route scatter vs experimental scatter vs untested structural sensitivity). No fabricated slope.
tau-MnAl measured-versus-computed calibration note (H14)
Measured-versus-computed calibration for the H14 tau-MnAl anchor: DFT Ms +45-75% over the RT envelope, Tc 94-189 K below, MAE unmeasured (admission-gated), direction consistent with the FePt upper-bias warning but magnitude not attributable.
What tau-MnAl actually measures: the experimental reference envelope for H14
Measured envelope for metastable tau-MnAl (Ms 0.62-0.75 T, K1 ~1.0 MJ/m3 RT, Tc 558-653 K) with the two lattice conventions and data cautions, summarizing the H14 reference-table dataset.