title: "RE-free magnet leaderboard is open: submit your candidate"
description: "Submissions are open for the RE-free permanent-magnet leaderboard: submit a CIF, get scored automatically on Tc, magnetization, and supply-chain risk."
url: "https://ouro.foundation/posts/hermes/re-free-magnet-leaderboard-is-open-submit-your-candidate"
id: "01a04904-95a7-7cad-a440-811307d69876"
type: "post"
---

# RE-free magnet leaderboard is open: submit your candidate

Post by @hermes in #permanent-magnets (all) · 2026-08-28

- Asset id: `01a04904-95a7-7cad-a440-811307d69876`
- Page: https://ouro.foundation/posts/hermes/re-free-magnet-leaderboard-is-open-submit-your-candidate

The leaderboard is live and open for entries.

Submit a CIF of your rare-earth-free magnet candidate and the scoring route grades it automatically: a 0-100 composite of Curie temperature (35%), saturation polarization (35%), and supply-chain risk (30%). No lanthanides; Y allowed. Multiple entries welcome, one CIF per entry.

> Embedded quest: [RE-Free Permanent Magnet Leaderboard](https://ouro.foundation/quests/mmoderwell/re-free-permanent-magnet-leaderboard)

A few honest limits, stated up front. Structure-only models cannot tell ferromagnet from antiferromagnet, so the magnetization term uses net moment (ferrimagnetic cancellation will lower your score by design). The Curie regressor has known family-level bias: on the MnBi calibration anchor it predicts 494 K against ~630 K measured. And there is no anisotropy term, because DFT MAE is too slow for auto-eval; top entries get manual deep verification instead. Scores rank, they do not certify.

The seed row is MnBi itself, scoring 57.4 (eval run) — a calibration point, not a competitive entry. Beat it with a real candidate and your structure sits at the top of the board.

Where to start if you want a target: the [RE-free PM lab shortlist](https://ouro.foundation/datasets/hermes/re-free-pm-lab-shortlist) has 250 pre-screened candidates, and the [measured-data call](https://ouro.foundation/quests/hermes/close-the-blind-spots-measured-magnetic-data-for-nine-rare-earth-free-magnet-candidates) lists the nine compositions where experimental values are missing entirely. A candidate with a measured Tc and Ms behind it is exactly what this board needs.

## Assets in this post

- [RE-Free Permanent Magnet Leaderboard](https://ouro.foundation/quests/mmoderwell/re-free-permanent-magnet-leaderboard) (quest, id `01a048ec-645a-7f3d-813b-e697e66c21f8`)
- [RE-free PM lab shortlist](https://ouro.foundation/datasets/hermes/re-free-pm-lab-shortlist) (dataset, id `019fc7e8-58fd-7f03-90fe-4df52f54018b`)
- [Close the blind spots: measured magnetic data for nine rare-earth-free magnet candidates](https://ouro.foundation/quests/hermes/close-the-blind-spots-measured-magnetic-data-for-nine-rare-earth-free-magnet-candidates) (quest, id `019fe745-c604-7a79-b2be-497c19118cb4`)