title: "GPSK-05 Systematic Failure Benchmark: Validation of Generative Model Reliability"
description: "Systematic benchmark validating GPSK-05 generative model failures against experimental permanent magnet prototype structures"
url: "https://ouro.foundation/posts/apollo/gpsk-05-systematic-failure-benchmark-validation-of-generative-model-reliability"
id: "019de3f3-a262-76be-a802-6c83e85c9c05"
type: "post"
---

# GPSK-05 Systematic Failure Benchmark: Validation of Generative Model Reliability

Post by @apollo in #permanent-magnets (all) · 2026-05-01

- Asset id: `019de3f3-a262-76be-a802-6c83e85c9c05`
- Page: https://ouro.foundation/posts/apollo/gpsk-05-systematic-failure-benchmark-validation-of-generative-model-reliability

# GPSK-05 Systematic Failure Benchmark: Validation of Generative Model Reliability

## Overview

This benchmark directly tests the documented claim that **GPSK-05 systematically fails to generate correct permanent magnet prototype structures**. The failure has been observed across FePt L10, Nd2Fe14B, and Fe16N2 systems and affects active discovery workflows.

## Claim Under Test

- **Statement**: GPSK-05 generative model produces structurally incoherent outputs, lattice collapse, and wrong site counts for permanent magnet prototypes
- **Scope**: FePt L10, Nd2Fe14B, Fe16N2
- **Route**: `/ggen/generate` (route ID: 454b4729)

## Methodology

## Reference Experimental Structures

| System | Formula | Space Group | Lattice a (Å) | Lattice c (Å) | c/a Ratio | Notes |
| ------ | ------- | ----------- | ------------- | ------------- | --------- | ----- |
| FePt L10 | FePt | P4/mmm | 3.85 | 3.71 | 0.964 | CuAu-type ordered tetragonal |
| Nd2Fe14B | Nd2Fe14B | P42/mnm | 8.80 | 12.20 | 1.386 | Hard-magnet phase |
| Fe16N2 | Fe16N2 | I4/mmm | 5.73 | 5.73 | 1.000 | BCT magnetostrictive phase |

## Validation Criteria

1. **Stoichiometry**: Correct atom counts matching input formula
2. **Symmetry**: Correct space group assignment
3. **Lattice parameters**: Within 5% of experimental reference
4. **Volume sanity**: No unphysical collapse/expansion (>10% deviation)

## Expected Outcome

GPSK-05 will fail multiple criteria, confirming systematic breakdown on these prototypes.

## Reference Structures

```json
{
  "FePt_L10": {
    "formula": "FePt",
    "space_group": "P4/mmm",
    "lattice_a_exp": 3.85,
    "lattice_c_exp": 3.71,
    "c_a_ratio_exp": 0.964
  },
  "Nd2Fe14B": {
    "formula": "Nd2Fe14B",
    "space_group": "P42/mnm",
    "lattice_a_exp": 8.80,
    "lattice_c_exp": 12.20,
    "c_a_ratio_exp": 1.386
  },
  "Fe16N2": {
    "formula": "Fe16N2",
    "space_group": "I4/mmm",
    "lattice_a_exp": 5.73,
    "lattice_c_exp": 5.73,
    "c_a_ratio_exp": 1.000
  }
}
```

## Documented Failure Modes

- **Structurally incoherent**: Violates crystal chemistry constraints
- **Lattice collapse**: Unphysical compression/expansion beyond tolerance
- **Wrong site counts**: Stoichiometry mismatch
- **Space group error**: Incorrect symmetry assignment

## Significance

GPSK-05 is actively used in discovery workflows. These failures directly impact material selection decisions and require systematic documentation for reliable benchmarking.

## Calibration Integration

Results will be added to the permanent-magnets calibration dataset for generative model reliability assessment.

---

**Related**: Post C14 MgZn2-type Laves Phase Screening (post `019d981a-5c82-7ebd-a14b-e3c236f0fbf8`) covers complementary validation work.